    150W Constant Current Electronical Load Battery Discharge Capacity Testing Tool
    Details
    PRODUCTION DETAILS
    Description:
    This is an electronic load board of very high cost performance, adopting two completely independent 18 bit ADC chip, 15 PPM voltage benchmark, which allows a high accuracy. It is better than other electronic load with single chip built-in AD sampling digital tube display or battery capacity tester. Supporting user second correction of parameters, it is a best choice for DIY users.
    Features:
    1602 LCD screen
    , display information comprehensively.
    Configuration of 9cm CPUfan, very quiet.
    With temperature display, supporting the discharge and voltage setting.
    Test all kinds of power load or burn-in, can also test capacity of battery discharge.
    Load maximum power 150W
    ,
    maximum voltage 60V
    ,
    maximum current 10A
    .
    Specifications:
    Voltage:
    DC 12V±5%
    Load Type:
    Constant current
    Load Voltage:
    0.5-60V
    Load Current:
    0-10A
    Maximum Power:
    150W
    Voltage ReadingPrecision:
    ±(0.1%+0.05%FS)
    Current ReadingPrecision:
    ±(0.2%+0.1%FS)
    Constant Current Accuracy:
    Current readingprecision + 1d
    Noise:
    25dD(A)
    Weight:
    341g(approx.)
    Instruction:
    1, Power: DC 12V, load power and power supply should be 2 independent power.
    2, Power on and screen shows "Welcome to use" which means equipment is normal
    3, Press "set" to move the cursor, add and subtract operations according to the cursor position. When the cursor position is at "I"
    or "V", press add and subtract button to switch voltage and current setting.
    4, Connect to power source that need to be tested, do not connect incorrectly of polarity.
    5, Press "start" button to start/stop electronic load, at the same time, the screen shows"ON" or "OF"
    6, Press "start" button more than 1 second to reset AH and time, at the same time power off the electronic load (if it's powered
    on)
    7, The lower left corner will display information that automatic switching by default every 2 seconds between power, AH,
    temperature, time. Press and hold "set" button, then press "add" button to switch, and the display information will not switch
    automatically. If you need the information to switch automatically again, press and hold "set" button, then press "subtract"
    button till lower right screen corner shows "Auto".
    8, Settings will be automatically saved after power down. Need to be manually started when power is back.
    9, Maximum power rate of load of continuous operation is associated with room temperature. When temperature is too high, operation
    power rate should be reduced. If the heat sink temperature reaches 87 ℃, the load will automatically reduce the power rate. When
    the core temperature reaches 91 ℃, it will stop work, and need to be manually started after cooling.
    10, Load current will be automatically adjusted according to the input voltage. For example, if set 10A, and the input voltage is
    20V, then it automatically change the actual current to 7.5A(150W/20V), even it still displays 10A.
    11, Reset first if need statistics of AH and time. It has been accumulating by default, will not automatically reset, and can only
    be reset manually.
    Notice:
    1, Power supply and load testing power supply must be independent, otherwise it may lead to uncontrollable load or other
    unpredictable situation.
    2, If the load is already started and then connect with test power, you need to assess whether power rate is secure. For example,
    if set 10A and start load, then connect to 60V power source, the instantaneous power rate can reach600W, which can probably damage
    power tube. Although the load current can adjusted automatically, but it need reactiontime (about 0.02 second). So when you are
    not sure if it is secure, you can connect it to test power supply first, and the machine will automatically calculate the largest
    secure current. For example, when the maximum voltage is 60V, the secure current is 2.5 A. If you set the current above 2.5A, it
    will work at 2.5A.
    3, Connect positive and negative of test power supply wrongly will cause short circuit, and if the current is too large, power
    tube may be damaged. Avoid reverse connection, please.
    4, Users need to have some knowledge of circuit.
    5, Suggest to power on the machine before connecting with test power supply or test batteries.
    Package Includes:
    1 x Electronic Load
    Note:
    Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.
    Payment
    Terms Of Sales
    About us
    Contact Us
    Payment
    We accept PayPal only.
    We only ship item to your PayPal verified address.
    Payment must be received within 3 days from the date of purchase.
    Orders will be processed instantly and dispatched in same day normally, so we do NOT accept any Email/Message note after you place orders.
    Terms Of Sales
    1. Our listing price includes the value of goods,packaging cost,and export
    taxes,not including international importduties.
    2. Importduties,taxes,and charges are not included in the item price or shipping fee.
    3. The importduties are buyers' responsibility.Please check with your country's
    customs office determine what these additional costs will be prior to your
    purchase.
    4. All disputes arising from the importduties will be submitted to eBay for solution.
    About us
    Any questions, pls. contact us via ebay message or email us.We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.
    If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "5stars" in very area.
    Our aim is to provide TopLevel Customer Service, your recognition will encourage us greatly and serve you better.
    We strive to keep all our customers satisfy.
    We greatly appreciate your POSITIVE feedback. Please do NOT leave negative feedback without asking for help.Thanks!
    Contact Us
    We will always do our up most to exceed your expectations in customer service, communication and dispatching of your orders.
    On Sep-20-20 at 23:49:05 PDT, seller added the following information: